SAME DAY SHIPPING ON ORDERS PLACED BY 4 PM VIA UPS | 877-288-8077

TE P&B CIRCUIT BREAKER W31-X2M1G-10

$39.95/Each
Part# 11-03931
MFR Model# W31-X2M1G-10
P & B Part No.AMP
Rating
BeechCessnaPiperPart No.
W31X2M1G1010---11-03931

Overview

These bi-metallic single pole breakers weigh less than 2 oz. and are especially suitable for homebuilt aircraft. Used as original equipment in Beech, Cessna and Piper aircraft. Maximum operating voltages: 32 VDC and 250 VAC (to 400 Hz).

Toggle Thermal Circuit Breaker
• 0.5 amp to 50 amp ratings may be used as on/off switch.
• Cannot be reset against overload.
• Screw termination.
• Trip-free operation.
   
California Prop 65 Warning Symbol

WARNING: Cancer and Reproductive Harm - www.P65Warnings.ca.gov.

Documents

  • Frequently Purchased With
  • Customers Also Viewed

Reviews

Antonio M Verified Purchase

TE P&B CIRCUIT BREAKER W31-X2M1G-10

November 28, 2023

Egil R Verified Purchase

TE P&B CIRCUIT BREAKER W31-X2M1G-10

July 23, 2023

A quality product at a reasonable price.

William J Verified Purchase

TE P&B CIRCUIT BREAKER W31-X2M1G-10

April 5, 2022

The picture of this breaker is correct however the part I received was reversed with the LOAD printed on the top terminal and LINE printed on the bottom.

Ed M Verified Purchase

TE P&B CIRCUIT BREAKER W31-X2M1G-10

March 22, 2022

This part was labeled incorrectly. All other circuit breakers have the LINE terminal on the top and LOAD terminal on the bottom.

Ed M Verified Purchase

TE P&B CIRCUIT BREAKER W31-X2M1G-10

March 22, 2022

Always quality from Spruce. Always a little pricey

John S Verified Purchase

TE P&B CIRCUIT BREAKER W31-X2M1G-10

February 12, 2022

fits where the old non pullable breaker was, now I can turn off some always on items for ground testing

Andy P Verified Purchase

TE P&B CIRCUIT BREAKER W31-X2M1G-10

January 14, 2022

Works Expensive shipping

Ian M Verified Purchase

TE P&B CIRCUIT BREAKER W31-X2M1G-10

September 15, 2021

I ordered it as a replacement for an identical one that failed with less than 15 hours on it. Well see how it goes, its survived 2 hours of operation so far.

Robert T Verified Purchase

TE P&B CIRCUIT BREAKER W31-X2M1G-10

July 21, 2021

Direct replacement to existing breaker. Easy to install and works perfectly.

John-mike
April 23, 2021

Q&A

Please note, Pilotshop.com's personnel are not certified aircraft mechanics and can only provide general support and ideas, which should not be relied upon or implemented in lieu of consulting an A&P or other qualified technician. Pilotshop.com assumes no responsibility or liability for any issue or problem which may arise from any repair, modification or other work done from this knowledge base. Any product eligibility information provided here is based on general application guides and we recommend always referring to your specific aircraft parts manual, the parts manufacturer or consulting with a qualified mechanic.

Q: Can you use these with a switch guard? I want to use two of these to run two fuel pumps and want to guard them whilst on so they cannot be bumped off. But - Can they still trip against the guard?

The arm is the same length as a toggle switch that would be used with at switch guard, so it "should" work fine. If the switch/breaker is positioned to be on when the guard is down, it would stay on until the guard is lifted and manually turned off. Remember each application is different and we cannot guarantee that it will work in all application or situations.

Q: Are these CB toggle switches FAA/PMA?

These toggle switches are commercial and have no FAA approval by themselves. They are commonly approved by the airframe approval if they were OEM on certificated aircraft. Please confirm in your parts manual or with you A&P to determine whether these can be used in your airplane.

Q: Can these breaker/switches be legally used to replace fuses in vintage certificated aircraft?

These toggle switches are commercial and have no FAA approval by themselves. They are commonly approved by the airframe approval if they were OEM on certificated aircraft. Please confirm in your parts manual AND with you A&P to determine whether these can be used in your airplane.

Q: These are marked load & line. Do they not require a ground wire? Thanks!

The line side is receiving power and the load side goes to the unit.

Q: if this item cannot be reset after an overload, how does it work again

It is not able to be reset while under an overload, if its is not overloaded it can be reset.

Q: Do these breakers have a trip indicator?

These do not have a visible trip indicator per the data sheet.